Search for collections on Repository Universitas Islam Riau

Pemetaan dan Identifikasi Kualitas Airtanah Dangkal Daerah Padat Penduduk di Kelurahan Babussalam, Kecamatan Mandau, Provinsi Riau

Aurell, Reza Dwi Poetri (2024) Pemetaan dan Identifikasi Kualitas Airtanah Dangkal Daerah Padat Penduduk di Kelurahan Babussalam, Kecamatan Mandau, Provinsi Riau. Other thesis, Universitas Islam Riau.

[thumbnail of 183610178_compressed.pdf] Text
183610178_compressed.pdf - Submitted Version
Restricted to Registered users only

Download (4MB) | Request a copy

Abstract

Babussalam Village is one of the villages included in the administrative area of Mandau District, Bengkalis Regency, Riau Province. Populated solid waste has the characteristic of containing high enough Phosphate and Nitrate. The research area is included in two formations, namely the Peasant Formation and the Minas Formation. The purpose of this study is to determine the distribution and direction of groundwater surface flow, the feasibility of groundwater quality physically and chemically, and determine the level of groundwater pollution around Babussalam Village, Mandau District, Riau Province. The methods used in this study are field sampling and laboratory analysis. The parameters tested are color, taste, odor, dissolved solids (TDS), electrical conductivity (DHL), pH, Phosphate (PO4), and Nitrate (NO3). The highest MAT values were at stations 1, 23 and 25 where the flow direction spread and flowed towards the central part of the study area, namely stations 16 and 28. The results of physical analysis in the study area of 30 stations, color parameters have clear colors 30 stations (100%), taste parameters 30 stations have a taste of no taste (100%), odor parameters 27 stations (90%) odorless and 3 stations (10%) odorless, TDS parameters 30 stations (100%) < 500 mg / l ranging from 17 – 206 mg / l. DHL parameters range from 34 – 380 ?S/cm. Based on the results of chemical parameter analysis pH values ranging from 7.69 – 7.83 at 30 stations, Phosphate Parameters 1 station (3%) has a value of > 0.2 mg / l and 29 stations (97%) have a value of < 0.2 mg / l. Nitrate Parameters 2 stations (7%) have a value of > 10 mg / l and 28 stations (93%) < 10 mg / l. Based on the results of the study, there are 5 stations, namely stations 2, 3, 8, 10 and 11 (17%) do not meet the Quality Standard Based on the Regulation of the Minister of Health No. 492 of 2010 and PP No. 82 of 2001 as water Drink or clean water

Item Type: Thesis (Other)
Contributors:
Contribution
Contributors
NIDN/NIDK
Sponsor
Adriati, Yolly
1018017303
Uncontrolled Keywords: Mandau Subdistrict, Solid Waste, Dug Wells, Groundwater Quality
Subjects: Q Science > QE Geology
T Technology > T Technology (General)
Divisions: > Teknik Geologi
Depositing User: Uthi kurnia S.IP
Date Deposited: 13 Sep 2025 08:09
Last Modified: 13 Sep 2025 08:09
URI: https://repository.uir.ac.id/id/eprint/28787

Actions (login required)

View Item View Item